Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian J Med Res ; 157(6): 509-518, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37322634

RESUMO

Background & objectives: Vaccination and natural infection can both augment the immune responses against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), but how omicron infection has affected the vaccine-induced and hybrid immunity is not well studied in Indian population. The present study was aimed to assess the durability and change in responses of humoral immunity with age, prior natural infection, vaccine type and duration with a minimum gap of six months post-two doses with either ChAdOx1 nCov-19 or BBV152 prior- and post-emergence of the omicron variant. Methods: A total of 1300 participants were included in this observational study between November 2021 and May 2022. Participants had completed at least six months after vaccination (2 doses) with either ChAdOx1 nCoV-19 or an inactivated whole virus vaccine BBV152. They were grouped according to their age (≤ or ≥60 yr) and prior exposure of SARS-CoV-2 infection. Five hundred and sixteen of these participants were followed up after emergence of the Omicron variant. The main outcome was durability and augmentation of the humoral immune response as determined by anti-receptor-binding domain (RBD) immunoglobulin G (IgG) concentrations, anti-nucleocapsid antibodies and anti-omicron RBD antibodies. Live virus neutralization assay was conducted for neutralizing antibodies against four variants - ancestral, delta and omicron and omicron sublineage BA.5. Results: Before the omicron surge, serum anti-RBD IgG antibodies were detected in 87 per cent participants after a median gap of eight months from the second vaccine dose, with a median titre of 114 [interquartile range (IQR) 32, 302] BAU/ml. The levels increased to 594 (252, 1230) BAU/ml post-omicron surge (P<0.001) with 97 per cent participants having detectable antibodies, although only 40 had symptomatic infection during the omicron surge irrespective of vaccine type and previous history of infection. Those with prior natural infection and vaccination had higher anti-RBD IgG titre at baseline, which increased further [352 (IQR 131, 869) to 816 (IQR 383, 2001) BAU/ml] (P<0.001). The antibody levels remained elevated after a mean time gap of 10 months, although there was a decline of 41 per cent. The geometric mean titre was 452.54, 172.80, 83.1 and 76.99 against the ancestral, delta, omicron and omicron BA.5 variants in the live virus neutralization assay. Interpretation & conclusions: Anti-RBD IgG antibodies were detected in 85 per cent of participants after a median gap of eight months following the second vaccine dose. Omicron infection probably resulted in a substantial proportion of asymptomatic infection in the first four months in our study population and boosted the vaccine-induced humoral immune response, which declined but still remained durable over 10 months.


Assuntos
COVID-19 , Humanos , Lactente , COVID-19/prevenção & controle , Imunidade Humoral , SARS-CoV-2 , ChAdOx1 nCoV-19 , Vacinação , Anticorpos Neutralizantes , Imunoglobulina G , Anticorpos Antivirais
2.
J Immunol ; 209(10): 2054-2067, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36426952

RESUMO

Commercial dengue virus (DENV) nonstructural-1 (NS1) Ag detection immunoassays often perform poorly, particularly in secondary DENV infection. To develop a highly sensitive NS1 ELISA, we generated a large repertoire of anti-DENV NS1 mouse mAbs (n = 95) that falls into 36 mAb classes based on binding specificities. The identified mAb pair, capable of efficiently detecting NS1 from four DENV serotypes in an immunoassay, was selected based on multiparametric analysis. The selected mAbs have subnanomolar affinities for NS1 with recognition sites outside the immunodominant wing domain. The assay was converted to an ELISA kit, which showed higher analytical sensitivity (3-fold to 83-fold) for NS1 from four DENV serotypes than commercial Platelia NS1 ELISA (Bio-Rad Laboratories). Compared to RT-PCR, the developed NS1 ELISA showed 78.57% (66 of 84) sensitivity, whereas Platelia NS1 ELISA showed a sensitivity of 60.71% (51 of 84). In a subgroup of RT-PCR-positive secondary dengue samples, our ELISA showed a sensitivity of 70.18% (40 of 57), whereas Platelia ELISA detected only 47.37% (27 of 57) samples. Furthermore, unlike Platelia ELISA, our test equally detected NS1 from four serotypes; Platelia ELISA performed poorly for the DENV-2 serotype, in which only 8 of 21 (38.10%) samples were detected compared with 17 of 21 (80.95%) in our ELISA. Moreover, our ELISA showed 100% specificity in 342 challenging dengue-negative samples. The large and diverse mAb repertoire generated against DENV NS1 and the appropriate selection of mAbs allowed us to establish an ELISA that can efficiently detect NS1 Ag even in secondary dengue and without serotype level bias.


Assuntos
Antineoplásicos Imunológicos , Vírus da Dengue , Dengue , Animais , Camundongos , Anticorpos Monoclonais , Ensaio de Imunoadsorção Enzimática , Epitopos Imunodominantes , Dengue/diagnóstico
3.
EBioMedicine ; 78: 103938, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35305396

RESUMO

BACKGROUND: Rapid spread of the omicron SARS-CoV-2 variant despite extensive vaccination suggests immune escape. The neutralising ability of different vaccines alone or with natural SARS-CoV-2 infection against omicron is not well-known. METHODS: In this cross-sectional study, we tested the ability of vaccine and natural infection induced antibodies to neutralise omicron variant in a live virus neutralisation assay in four groups of individuals: (i) ChAdOx1 nCoV-19 vaccination, (ii) ChAdOx1 nCoV-19 vaccination plus prior SARS-CoV-2 infection, (iii) vaccination with inactivated virus vaccine (BBV152), and (iv) BBV152 vaccination plus prior SARS-CoV-2 infection. Primary outcome was fold-change in virus neutralisation titre against omicron compared with ancestral virus. FINDINGS: We included 80 subjects. The geometric mean titre (GMT) of the 50% focus reduction neutralisation test (FRNT50) was 380·4 (95% CI: 221·1, 654·7) against the ancestral virus with BBV152 vaccination and 379·3 (95% CI: 185·6, 775·2) with ChAdOx1 nCov-19 vaccination alone. GMT for vaccination plus infection groups were 806·1 (95% CI: 478·5, 1357·8) and 1526·2 (95% CI: 853·2, 2730·0), respectively. Against omicron variant, only 5 out of 20 in both BBV152 and ChAdOx1 nCoV-19 vaccine only groups, 6 out of 20 in BBV152 plus prior SARS-CoV-2 infection group, and 9 out of 20 in ChAdOx1 nCoV-19 plus prior SARS-CoV-2 infection group exhibited neutralisation titres above the lower limit of quantification (1:20) suggesting better neutralisation with prior infection. A reduction of 26·6 and 25·7 fold in FRNT50 titres against Omicron compared to ancestral SARS-CoV-2 strain was observed for individuals without prior SARS-CoV-2 infection vaccinated with BBV152 and ChAdOx1 nCoV-19, respectively. The corresponding reduction was 57·1 and 58·1 fold, respectively, for vaccinated individuals with prior infection. The 50% neutralisation titre against omicron demonstrated moderate correlation with serum anti-RBD IgG levels [Spearman r: 0·58 (0·41, 0·71)]. INTERPRETATION: Significant reduction in the neutralising ability of both vaccine-induced and vaccine plus infection-induced antibodies was observed for omicron variant which might explain immune escape. FUNDING: Department of Biotechnology, India; Bill & Melinda Gates Foundation, USA.


Assuntos
Vacinas contra COVID-19 , COVID-19 , COVID-19/prevenção & controle , ChAdOx1 nCoV-19 , Estudos Transversais , Humanos , SARS-CoV-2 , Vacinas de Produtos Inativados
4.
Anal Biochem ; 593: 113574, 2020 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-31911046

RESUMO

Owing to their ease in operation and fast turnaround time, lateral flow assays (LFAs) are increasingly being used as point-of-care diagnostic tests for variety of analytes. In a majority of these LFAs, antibodies are used as a molecular recognition element. Antibodies have a number of limitations such as high batch-to-batch variation, poor stability, long development time, difficulty in functionalization and need for ethical approval and cold chain. All these factors pose a great challenge to scale up the antibody-based tests. In recent years, the advent of aptamer technology has made a paradigm shift in the point-of-care diagnostics owing to the various advantages of aptamers over antibodies that favour their adaptability on a variety of sensing platforms including the lateral flow. In this review, we have highlighted the advantages of aptamers over antibodies, suitability of aptamers for lateral flow platforms, different types of aptamer-based LFAs and various labels for aptamer-based LFAs. We have also provided a summary of the applications of aptamer technology in LFAs for analytical applications.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Testes Imediatos , Técnica de Seleção de Aptâmeros/métodos , Humanos
5.
Front Mol Biosci ; 7: 586254, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33425988

RESUMO

The gold standard for the diagnosis of SARS-CoV-2, the causative agent of COVID-19, is real-time polymerase chain reaction (PCR), which is labor-intensive, expensive, and not widely available in resource-poor settings. Therefore, it is imperative to develop novel, accurate, affordable, and easily accessible assays/sensors to diagnose and isolate COVID-19 cases. To address this unmet need, we utilized the catalytic potential of peroxidase-like DNAzyme and developed a simple visual detection assay for SARS-CoV-2 RNA using a conventional thermal cycler by the PCR-induced generation of DNAzyme sensor. The performance of RT-PCR DNAzyme-based sensor was comparable to that of real-time PCR. The pilot scale validation of RT-PCR DNAzyme-based sensor has shown ~100% sensitivity and specificity in clinical specimens (nasopharyngeal swab, n = 34), with a good correlation (Spearman r = 0.799) with the Ct-value of fluorescence probe-based real-time PCR. These findings clearly indicate the potential of this inexpensive, sensitive, and specific molecular diagnostic test to extend our testing capabilities for the detection of SARS-CoV-2 to curtail COVID-19 transmission.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...